[GENERAL INFORMATION] Function Name=FTIR CR Brief Description=Fit FTIR Magneto Transmission Function Source=N/A Function Type=User-Defined Function Form=Y-Script Number Of Parameters=7 Number Of Independent Variables=1 Number Of Dependent Variables=1 [FITTING PARAMETERS] Naming Method=User-Defined Names=Offset,n0,n1,m_eff,Field,Ns,mu Meanings=refr. ind. of SiO, and Si, eff. mass, Field, el. conc. in 10^12, mobility Initial Values=--(V) Lower Bounds=--(X,OFF) Upper Bounds=--(X,OFF) Number Of Significant Digits= [FORMULA] wc=0.17585*Field/m_eff; w=0.188365*x; tau=5.6866e-4*m_eff*mu; wps=0.10613*Ns/(m_eff*(n0+n1)); A=((w - wc)^2 * tau^2 + 1); B=((w + wc)^2 * tau^2 + 1); C=wps*tau*(wps*tau + 2); beta=n0/(n0 + n1); y=Offset+2*beta^2*(A/(A+C)+B/(B+C)); [CONSTRAINTS] /*Enter general linear constrainats here*/ [CONSTANTS] [INITIALIZATIONS] /*Scripts to be executed before fitting, a good place for complicated initialization.*/ [AFTER FITTING] /*Scripts to be executed after fitting, a good place for generating results.*/ [INDEPENDENT VARIABLES] x= [DEPENDENT VARIABLES] y= [CONTROLS] General Linear Constraints=Off Initialization Scripts=Off Scripts After Fitting=Off Number Of Duplicates=N/A Duplicate Offset=N/A Duplicate Unit=N/A Generate Curves After Fitting=Yes Curve Point Spacing=Same X as Fitting Data Generate Peaks After Fitting=Yes Generate Peaks During Fitting=Yes Generate Peaks with Baseline=Yes Paste Parameters to Plot After Fitting=Yes Paste Parameters to Script Window After Fitting=Yes Generate Residue After Fitting=Yes Keep Parameters=No